Positive Volume Index PVI
A running index that moves with the close's change only on bars whose volume rose from the bar before, and stands still on the others.
It measures what price did on the busier bars.
01The study, live
Computed by Bentrix’s own code over the same synthetic bars on every page — an illustration of how the study behaves, not a market.
What this figure shows
The figure is computed over 300 sample bars, and PVI has a value from the first. Its line runs between 999.3 and 1,012 on these bars, and the last value is 1,005. Counting the conditions the study declares on these bars: turns up 56 times; turns down 60 times. Press a condition under the figure to see each place marked. As states rather than moments: is rising on 73 bars; is falling on 72 bars.
02Its parts, named
03What you see
The Positive Volume Index changes only on bars whose volume rose — following busy bars.
PVI is one line in a pane of its own. It moves in steps: flat on every bar whose volume fell from the bar before, and moving by the close's percentage change on every bar whose volume rose. Its level depends on where the history begins.
04Where it comes from
The Positive Volume Index is the companion of the NVI, from the same work of Paul Dysart and Norman Fosback: it follows price only on days when volume rose — the days, on the premise, when the crowd is active.
05The formula
PVIₜ = { PVI_(t−1)(1 + (Cₜ − C_(t−1))/(C_(t−1))) if Vₜ > V_(t−1); PVI_(t−1) otherwise } PVI₀ = 100006A worked example
The sample bars used here are eight: closes 20, 21, 23, 22, 24, 25, 24, 26; highs 21, 22, 24, 24, 25, 26, 26, 27; lows 18, 19, 20, 21, 21, 23, 23, 23; opens 19, 20, 21, 23, 22, 24, 25, 24; volumes 100, 120, 150, 90, 140, 160, 80, 170.
The index starts at 1,000. On a bar whose volume is higher than the previous bar's, it changes by the close's percentage change; otherwise it stays.
- bar 2: volume 120 > 100, close 20 → 21 (+5.00 %): 1050.00
- bar 3: volume 150 > 120, close 21 → 23 (+9.52 %): 1150.00
- bar 4: volume fell, no change
- bar 5: volume 140 > 90, close 22 → 24 (+9.09 %): 1254.55
and it ends at 1415.72. Every rise in these bars came on rising volume, so the PVI carries the whole advance.
07Built in Assay
The same study written in Assay, Bentrix’s script language, and drawn by Bentrix itself as the script’s graph: each block is one step of the formula. On the ladder the steps stand in the script’s order, one a row; on the board each wire carries a value from the block that gives it to the block that reads it, left to right. The script computes exactly what the study computes — Bentrix checks the two against each other, candle by candle.
//@version=6 indicator("Positive Volume Index") // Starts at 1000 and follows the close's change only on bars whose volume rose. var float pvi = 1000.0 if bar_index > 0 and volume > volume[1] and close[1] != 0 pvi := pvi * (1 + (close - close[1]) / close[1]) plot(pvi, "PVI")
Paste it into the Assay IDE to put it on a chart, or to change it. Looking at the graph is free in every package; editing it as blocks is Plus.
08Readings — what traders look for
Read like the OBV: direction and divergences.
Against its long average. Fosback compared it with its one-year average, as with the NVI, and found it the weaker of the two as a guide. The tendency belongs to daily stock-index data.
How it fails on tick volume. On markets without a central tape (spot forex, most CFDs) the volume is one broker's count of price changes, not traded size. The study then measures activity on that feed; two brokers give two lines.
09In different markets and timeframes
The Positive Volume Index moves only on bars whose volume rose. It follows price on the busy days and is the weaker half of Fosback's pair.
It needs a volume that is comparable from bar to bar: daily volume of an exchange-traded instrument or an index. On currency feeds the volume is a tick count that rises with volatility, so the busy bars it follows are simply the volatile ones. On intraday bars volume rises at every open and the split into rising and falling bars follows the clock. Its level depends on where the history begins, so it is compared with its own average and not across instruments.
10With other studies
Read beside the NVI; between them they account for every bar's change once.
11What it does not tell you
It does not show what the crowd did; it shows price on bars where volume happened to rise.
12Inputs and defaults
- 1Timeframe — ChartThe chart's own by default; any higher one, read on the last closed candle. A finer one is never offered.
- 2Wait for the candle to close — OnThe value of a higher timeframe is taken only from a candle that has finished.
What each input changes
- TimeframeThe study has no numeric input. It starts at 1,000 on the first bar of the history.
- In useIt has no input.
13Limits and common misreadings
Start-dependent level. The index is a running product from the first bar of the history, so its level differs with where the history begins; only its shape and its position against its own average are read.
It ignores every bar on which volume fell. On those bars the line is flat, whatever price did.
14Conditions an alert or a strategy can watch
an event happens on one bar a state holds on every bar while it lasts
These are the conditions the study itself declares — the same rules the alert editor and the strategy engine read, and the ones the figure's chips show.
15Practise it in the laboratory
Put PVI and the close in two panes; find a stretch where price rose and the PVI was flat, and read the volumes there.
Open the laboratory17In Bentrix
- From the menu: a chart's Indicators button › Volume › PVI, or type PVI in its search.
- Its settings: the settings card opens when it is added; its legend's name opens it again.
18From an agent or a program
Two tools reach it. study_values computes it over a workbench’s candles up to the clock — no chart needed — and study_attach puts it on a chart, where it is drawn and saved with the chart ({"chart": "<chart uri>", "kind": "pvi"}).
The study, as a chart files it
This is a new PVI’s entry — its kind, its calculation, the price it reads and its settings. Change a setting here to read it with other inputs.
{
"applied": "close",
"convention": "talib",
"kind": "pvi",
"settings": {
"shape": "ta",
"values": {}
}
}An agent
An agent calls the MCP tool with it:
{
"name": "study_values",
"arguments": {
"bench": "bentrix://lab/\u2026/bench/\u2026",
"symbol": "EURUSD",
"timeframe": "H1",
"limit": 5,
"study": {
"applied": "close",
"convention": "talib",
"kind": "pvi",
"settings": {
"shape": "ta",
"values": {}
}
}
}
}A program
A program does the same in its language — bench and market as in the built-in indicators guide:
Python
values = client.study.values(bench, market, "H1", {"applied": "close", "convention": "talib", "kind": "pvi", "settings": {"shape": "ta", "values": {}}}, limit=5)
print("times:", values["times"])
for line in values["lines"]:
print("line:", line["line"])
print(" newest values:", line["values"])JavaScript
const values = await client.study.values({ bench, symbol: market, timeframe: "H1", study: { "applied": "close", "convention": "talib", "kind": "pvi", "settings": { "shape": "ta", "values": { } } }, limit: 5 });
console.log("times:", values.times);
for (const line of values.lines) {
console.log("line:", line.line);
console.log(" newest values:", line.values);
}C#
var values = await client.Study.Values(bench, market, "H1", new Dictionary<string, object?> { ["applied"] = "close", ["convention"] = "talib", ["kind"] = "pvi", ["settings"] = new Dictionary<string, object?> { ["shape"] = "ta", ["values"] = new Dictionary<string, object?> { } } }, limit: 5);
Console.WriteLine($"times: {values!["times"]!}");
foreach (var line in values!["lines"]!.AsArray())
{
Console.WriteLine($"line: {line!["line"]!}");
Console.WriteLine($" newest values: {line!["values"]!}");
}Go
values := must(client.Study.Values(ctx, mcp.StudyValuesArgs{Bench: bench, Symbol: market, Timeframe: "H1", Study: map[string]any{"applied": "close", "convention": "talib", "kind": "pvi", "settings": map[string]any{"shape": "ta", "values": map[string]any{}}}, Limit: mcp.Ptr[int64](5)}))
fmt.Println("times:", at(values, "times"))
for _, line := range at(values, "lines").([]any) {
fmt.Println("line:", at(line, "line"))
fmt.Println(" newest values:", at(line, "values"))
}Java
Object values = client.study.values(new Bentrix.StudyApi.ValuesArgs(bench, market, "H1", obj("applied", "close", "convention", "talib", "kind", "pvi", "settings", obj("shape", "ta", "values", obj()))).limit(5L));
System.out.println("times:" + " " + at(values, "times"));
for (Object line : (List<Object>) at(values, "lines")) {
System.out.println("line:" + " " + at(line, "line"));
System.out.println(" newest values:" + " " + at(line, "values"));
}C++
auto values = client.study.values_(StudyApi::ValuesArgs(bench, market, "H1", Json::Object{{"applied", "close"}, {"convention", "talib"}, {"kind", "pvi"}, {"settings", Json::Object{{"shape", "ta"}, {"values", Json::Object{}}}}}).limit(5));
std::cout << "times:" << " " << values["times"].dump() << std::endl;
for (const Json &line : values["lines"].arr()) {
std::cout << "line:" << " " << line["line"].dump() << std::endl;
std::cout << " newest values:" << " " << line["values"].dump() << std::endl;
}Julia
values = client.study.values(bench, market, "H1", Dict{String,Any}("applied" => "close", "convention" => "talib", "kind" => "pvi", "settings" => Dict{String,Any}("shape" => "ta", "values" => Dict{String,Any}())); limit = 5)
println("times:", " ", values["times"])
for line in values["lines"]
println("line:", " ", line["line"])
println(" newest values:", " ", line["values"])
endR
values <- client$study$values(bench, market, "H1", list(applied = "close", convention = "talib", kind = "pvi", settings = list(shape = "ta", values = list())), limit = 5)
cat("times:", format(values$times), "\n")
for (line in values$lines) {
cat("line:", format(line$line), "\n")
cat(" newest values:", format(line$values), "\n")
}Rust
let values = client.study().values(mcp::StudyValuesArgs::new(bench.clone(), market.clone(), "H1", serde_json::json!({"applied": "close", "convention": "talib", "kind": "pvi", "settings": {"shape": "ta", "values": {}}})).limit(5))?;
println!("times: {}", values["times"]);
for line in values["lines"].as_array().into_iter().flatten() {
println!("line: {}", line["line"]);
println!(" newest values: {}", line["values"]);
}Reading the answer
times— the candles’ open times, in milliseconds since 1970 (UTC), oldest first.lines— one entry per line, in this order, each with itslinename and itsvalues;values[i]belongs to the candle attimes[i].- The last value is the candle at the clock’s, which may still be forming: it changes until that candle closes, as on the chart. Nothing after the clock is ever computed.
nullis a candle with no value yet — the warm-up, about 1 × the period at the start of the history.
line | What it is |
|---|---|
Main | the indicator's own value |
In a strategy
Filed under a key of your choice in a strategy document’s studies — here pvi: {"pvi": {"applied": "close", "convention": "talib", "kind": "pvi", "settings": {"shape": "ta", "values": {}}}} — its rules can name:
| Write | What it is |
|---|---|
pvi | its main line, as a value in a compare |
{"cond": "pvi:line.turns_up"} | a condition it declares itself |
{"cond": "pvi:line.turns_down"} | a condition it declares itself |
{"cond": "pvi:line.rising"} | a condition it declares itself |
{"cond": "pvi:line.falling"} | a condition it declares itself |
19Sources
- Colby, Robert W. The Encyclopedia of Technical Market Indicators, 2nd ed. McGraw-Hill, 2003.
- Fosback, Norman G. Stock Market Logic. Institute for Econometric Research, 1976.
Bentrix 0.1.382Every number, name and default on these pages is read from the application itself.What is comingWhat changed